This option allows the user to pipe data from their application to a
queue, provided the application is able to directly use a pipe.
FTSpooler generates a pipe called \\ServerName\pipe\QueueName (where
ServerName is replaced with "." (dot) if writing from an application on
the FormTrap server to the queue on the same machine).
To configure the named pipes options:
- Tick the Enable at start-up
checkbox to enable pipes at FTSpooler start-up.
- Enter the Pipe prefix.
- Press Save
Start or Stop
and Start the service and check Current
state is Ready.
More information on Submit Queue via
Named Pipes

If you have other applications using pipes,
you can prevent conflict by using more of the prefix to uniquely
identify FormTrap pipes. In this case, consider a prefix of "\\.\pipe\ft-" to identify
FormTrap pipes (ft- can
be whatever you require). The final pipe name might be "\\.\pipe\ft-invoices".
|